Welcome to Francis Academic Press

Frontiers in Medical Science Research, 2023, 5(7); doi: 10.25236/FMSR.2023.050712.

Compressed Sense Technique in Cranial Magnetic Resonance Angiography

Author(s)

Gaoyuan Liu

Corresponding Author:
Gaoyuan Liu
Affiliation(s)

Department of Radiology, Deyang People’s Hospital, Deyang, Sichuan, China

Abstract

In recent years, Compressed Sense technology has emerged as a promising image reconstruction method, demonstrating great potential in reducing data acquisition time and improving image quality. This study aims to explore the application of compressed sense technology in cerebral magnetic resonance angiography (MRA), compare it with conventional vascular imaging techniques, and evaluate its advantages in clinical practice. The study utilized a Philips Ingenia 3.0T magnetic resonance imaging (MRI) system and included a certain number of normal subjects and patients with cerebral vascular lesions. Both conventional vascular imaging techniques and compressed sense technology were employed for scanning, and the differences between the two methods in terms of image quality, acquisition time, and other aspects were compared. Image quality assessment indicators included overall image quality, blood vessel display clarity, and blood vessel contrast, among others. Additionally, the application of both techniques in specific clinical cases was analyzed. The results showed that, compared to conventional vascular imaging techniques, compressed sense technology significantly shortened the scanning time while ensuring image quality. In the detection of certain diseases such as cerebral aneurysms and ischemic cerebrovascular lesions, compressed sense technology not only effectively improved the clarity and contrast of blood vessel display but also made the detection process more convenient and accurate. Moreover, for patients with severe movement disorders or those who cannot tolerate long scanning times, compressed sense technology is a more suitable choice. In conclusion, compressed sense technology exhibits significant advantages in cerebral MRA. It demonstrates clear advantages over conventional vascular imaging techniques in terms of image quality, acquisition time, and other aspects, and it has high application value in the detection of specific diseases. We recommend the extensive application of compressed sense technology in clinical practice and further exploration of its application in other areas of MRI imaging.

Keywords

Cephalometric, Magnetic resonance, Angiography, compressed perception, Philips Ingenia 3.0T, Clinical applications

Cite This Paper

Gaoyuan Liu. Compressed Sense Technique in Cranial Magnetic Resonance Angiography. Frontiers in Medical Science Research (2023) Vol. 5, Issue 7: 75-82. https://doi.org/10.25236/FMSR.2023.050712.

References

[1] Chu Jonathan,Basyuni Shadi,Moore Samuel,Ferro Ashley,Chang Cherry,Patel Krishna,Jeremiah Huw, Brassett Cecilia,Santhanam Vijay. A Novel Cephalometric Approach Aiming to Quantify a Normal Range of Bony Chin Protrusion[J]. Journal of Maxillofacial and Oral Surgery,2022,22(1).

[2] Harada Yohei,Kairamkonda Supriya R,Ilyas Ushna,Pothineni Naga V K,Samant Rohan S,Shah Vishank A,Kapoor Nidhi,Onteddu Sanjeeva,Nalleballe Krishna. Pearls & Oy-sters: Contrast-induced encephalopathy following coronary angiography: A rare stroke mimic.[J]. Neurology,2020,94(23).

[3] Tay ASS, Maya M, Moser FG, Nuño M, Schievink WI. Computed Tomography vs Heavily T2-Weighted Magnetic Resonance Myelography for the Initial Evaluation of Patients With Spontaneous Intracranial Hypotension[J]. JAMA Neurology,2021.

[4] Rajasekaran Abirami,Veerasekaran Anuradha. Questions regarding the cephalometric evaluation of intrusion of maxillary posterior teeth[J]. American Journal of Orthodontics & Dentofacial Orthopedics, 2022,162(3).

[5] Zhang Zihan,Liao Wen,Xiong Xin,Zhu Rui,Wang Jun. Evaluation of online game-based and traditional teaching methods in cephalometric landmarks identifications.[J]. American journal of orthodontics and dentofacial orthopedics: official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics,2022,161(6).

[6] Arai Juichi,Nakahigashi Rie,Sugiyama Teruyasu. Study on Cycle Life of Lithium-Ion Batteries Using in Situ 7li Solid-State Nuclear Magnetic Resonanc[J]. Meeting Abstracts,2015,MA2015-03(2).

[7] Paloma Malagón,Cristian Carrasco,Oihane García,María Del-Río,Carmen Higueras. Reply to: “When to assess the flap perfusion by intraoperative indocyanine green angiography (ICGA): On the donor site or the recipient site?”[J]. The Breast,2020,52(prepublish).

[8] Arroyo R.,Higano N.,Bates A.,Woods J. C.,Kingma P. S.. Magnetic Resonance Imaging (MRI) Analysis of the Dynamic Tracheal Collapse During Breathing in Infants with Esophageal Atresia/Tracheoesophageal Fistula[J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE,2020,201.

[9] Franzini Andrea,Moosa Shayan,Prada Francesco,Elias W Jeffrey. Ultrasound Ablation in Neurosurgery: Current Clinical Applications and Future Perspectives.[J]. Neurosurgery,2020,87(1).

[10] Gil SooMin,Kim Inhwan,Cho JinHyoung,Hong Mihee,Kim Minji,Kim SuJung,Kim YoonJi,Kim Young Ho,Lim SungHoon,Sung Sang Jin,Baek SeungHak,Kim Namkug,Kang KyungHwa. Accuracy of auto-identification of the posteroanterior cephalometric landmarks using cascade convolution neural network algorithm and cephalometric images of different quality from nationwide multiple centers.[J]. American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics, 2022,161(4).

[11] Fani Memi,Aglaia Ntokou,Irinna Papangeli. CRISPR/Cas9 GENE-EDITING: RESEARCH TECHNOLOGIES, CLINICAL APPLICATIONS AND ETHICAL CONSIDERATIONS[J]. Seminars in Perinatology,2018,42(8).

[12] Ahsan Lusana,Zheng Wen,Kaur Gurleen,Kadakuntla Anusri,Remaley Alan,Sampson Maureen, Feustel Paul, Nappi Anthony,Mookherjee Sulagna,Lyubarova Radmila. ASSOCIATION OF LIPOPROTEIN SUBFRACTIONS WITH PRESENCE AND SEVERITY OF CORONARY ARTERY DISEASE IN STATIN-NAÏVE PATIENTS REFERRED FOR CORONARY ANGIOGRAPHY[J]. Journal of the American College of Cardiology,2021,77(18S1).

[13] Ramakrishnan Meera S,Ehlers Justis P,Modi Yasha S. The Clinical Signal-to-Noise Ratio of OCT Angiography: Key Applications for Routine Clinical Use.[J]. Ophthalmology. Retina,2022,6(9).

[14] Zhifeng Chi. Research on satellite remote sense image fusion algorithm based on compressed perception theory[J]. Journal of Computational Methods in Sciences and Engineering,2020,21(2).

[15] Blanche Bapst,Jean-Louis Amegnizin,Alexandre Vignaud,Paul Kauv,Anne Maraval,Erwah Kalsoum, Titien Tuilier,Azzedine Benaissa,Pierre Brugières,Xavier Leclerc,Jérôme Hodel. Post-contrast 3D T1-weighted TSE MR sequences (SPACE, CUBE, VISTA/BRAINVIEW, isoFSE, 3D MVOX): Technical aspects and clinical applications[J]. Journal of Neuroradiology,2020,47(5).

[16] Hutchison Cathy,Morrison Audrey,Rice Ann Marie,Tait Gemma,Harden Sharon. Provision of information about malignant spinal cord compressed: perceptions of patients and staff.[J]. International journal of palliative nursing,2012,18(2).

[17] Yahyah Aman,Johannes Frank,Sofie Hindkjær Lautrup,Adrian Matysek,Zhangming Niu,Guang Yang, Liu Shi,Linda H. Bergersen,Jon Storm-Mathisen,Lene J. Rasmussen,Vilhelm A. Bohr,Hilde Nilsen,Evandro F. Fang. The NAD + -mitophagy axis in healthy longevity and in artificial intelligence-based clinical applications[J]. Mechanisms of Ageing and Development,2020,185(C).

[18] Reem S, Sarrah E, Christopher D. Re-audit of indications for plain abdominal films from the emergency department in Queen Elizabeth Hospital, Gateshead[J].Clinical Radiology, 2018, 73:e25.

[19] Sheng CANG,A-chuan WANG. Research on compressed Perceptual Hyperspectral Image Reconstruction Based on GISMT[P]. DEStech Transactions on Computer Science and Engineering, 2018.

[20] R.K. Segoenyane,W.I.D. Rae,A. Conradie. Installation process for a Philips Ingenia 3 Tesla magnetic resonance imaging unit at Universitas Academic Hospital[J]. Physica Medica,2015,31.

[21] Sun Y,Wang J. Image Preprocessing Technology of Screen Coding Based on compressed Perception[C]//Advanced Science and Industry Research Center.Proceedings of 2017 2nd International Conference on Automation, Mechanical and Electrical Engineering (AMEE2017). Atlantis Press, 2017:236-240.

[22] Dalin Tang and Zhiyong Li. Preface: Innovations and Current Trends in Computational Cardiovascular Modeling and Beyond: Molecular, Cellular, Tissue and Organ Biomechanics with Clinical Applications[J]. CMES: Computer Modeling in Engineering & Sciences,2018,116(2).