The Frontiers of Society, Science and Technology, 2020, 2(4); doi: 10.25236/FSST.2020.020412.
Li Bo, Yu Haiyang, Shen Leyang
Yalong River Hydropower Development Company, Ltd. ErTan HydroPower Station, PanZhiHua 617000, China
A hydropower station is an axial-flow propeller turbine unit with a installed capacity of 4 * 150MW and a rated head of 20m. The treatment of head sampling and the improvement of fault judgment will directly affect the stability and reliability of the load adjustment of the unit. By analyzing the load fluctuation event caused by a certain head failure, the water head processing logic of the governor control system was modified and improved, and relevant verification tests were carried out to achieve the expected purpose and effect, hoping to provide reference for peers.
Urbine governor; Head treatment; Perfect logic; Load fluctuation
Li Bo, Yu Haiyang, Shen Leyang. Optimization of Water Head Processing Logic for Governor Control System of a Power Station. The Frontiers of Society, Science and Technology (2020) Vol. 2 Issue 4: 46-49. https://doi.org/10.25236/FSST.2020.020412.
[1] Ronghong (20011). Microcomputer Turbine Governor Teaching Material (Third Edition) no.2, pp.45-46.