Abstract

This article studies the electromagnetic compatibility of a certain type of ozone therapy instrument, and conducts research on the electrical fast transient pulse group test project. First, analyze the working principle of the product, and then test according to the test standard. After the product has a problem, perform problem diagnosis and analysis. Finally, two methods to improve the reliability of the product's electromagnetic compatibility are given, and the correctness of the method is proved through experiments And reliability, provide a basis for the actual electromagnetic compatibility rectification.

Keywords

electromagnetic compatibility, ozone therapy device, electrical fast transient pulse group, case rectification

Cite This Paper

Yongan Wang, Yiqun Sun, Xudong Zhao. Case Analysis of Electromagnetic Compatibility Correction for Electrical Fast Transient (EFT). International Journal of Frontiers in Engineering Technology (2020), Vol. 2, Issue 2: 123-130. https://doi.org/10.25236/IJFET.2020.020213.

References

[1] Zhai Xiaoshe, Geng Yingsan, Wang Jianhua, Song Zhengxiang, Zhang Guogang. Modeling of electrical fast transient pulse group immunity test generator[J]. Proceedings of the Chinese Society of Electrical Engineering, 2010, 30(06): 123-128.
[2] Shao Yuda, Zhang Yuhuan, Deng Lingxiang, Zhou Lei, Wu Pinghong. EFT optimized inductor design in electromagnetic compatibility of electronic equipment[J]. Journal of Nanjing Normal University (Engineering Technology Edition), 2011, 11(03): 10-12+30 .
[3] Dou Aiyu, Zhao Yang, Yan Wei, Ci Wenyan, Wang Jue. Case analysis of electric fast transient pulse group test of locomotive auxiliary power supply[J]. Journal of Nanjing Normal University (Engineering Technology Edition), 2014, 14(02): 19-23.
[4] Zhang Sanqing. Research on the mechanism and suppression technology of electrical fast transient pulse group and surge interference[D]. North China Electric Power University (Hebei), 2004.
[5] Niu Haijun. EFT test and performance analysis of electronic equipment[D]. University of Electronic Science and Technology of China, 2010.
[6] Cao Heng, Wang Qi,Zhang Jinsuo, Yuan Huimin. Research on Test Method of Electrical Fast Transient Pulse Group[J]. Vibration, Testing & Diagnosis, 2006(04): 278-281+330.
[7] Zhang Jie. Research on the generation mechanism and suppression method of electrical fast transient pulse group[D]. China University of Petroleum (East China), 2013.
[8] Chen Shigang. Suppression of Electrical Fast Transient Pulse Group[J]. Safety and Electromagnetic Compatibility, 1997(04): 7-13+24.