Abstract

Steel-concrete composite structures have been widely used in developed countries such as various countries. China's composite structures started relatively late, but since the reform and opening up, such structures have been studied extensively.  The role of shear connectors is to prevent the horizontal sliding and separation of the two at the interface, so that steel structures and concrete structures with very different elastic moduli form a whole and work together.  The ideal design of shear connectors should provide sufficient and complete combined action for the structure and focus on testing the shear resistance of channel steel shear connectors of reinforced concrete slabs under monotonic loading.  The types of shear connectors in steel-concrete composite structures are further studied.Based on the measured data, based on the existing common shear connectors, the type, function and design requirements of the shear connectors can be divided into the linearity before the external load reaches the yield bearing capacity. The stage, the load is increased from the yield bearing capacity to the plastic phase of the ultimate bearing capacity and the failure phase.

Keywords

Measured data; Steel-concrete composite structure; Shear connectors

Cite This Paper

Hengnan Mo, Hetao Hou, Jianguo Nie, Li Tian, Min Wang. Experimental Study on Shear Connectors in Steel-concrete Composite Structures Based on Measured Data. Academic Journal of Engineering and Technology Science (2019) Vol. 2 Issue 2: 1-8. https://doi.org/10.25236/AJETS.020036.

References

[1] Allahyari H,M. Nikbin I,Rahimi R. S,et al. A new approach to determine strength of Perfobond rib shear connector in steel-concrete composite structures by employing neural network[J]. Engineering Structures, 2018, 157:235-249.
[2] Balasubramanian R,Rajaram B.Study on behaviour of angle shear connector in steel-concrete composite structures[J]. International Journal of Steel Structures, 2016, 16(3):807-811.
[3] Su Q T,Yang G T,Li C X.Structural behaviour of perforated shear connectors with flange heads in composite girders: an experimental approach[J]. International Journal of Steel Structures, 2014, 14(1):151-164.
[4]Fan L,Zhou Z.New Shear Connectors Based on PBL Shear Connector For Composite Arch Members[J]. Structural Engineering International, 2014, 24(2):281-284.
[5] Kopp M,Feldmann M,Cla?En M,et al. Untersuchungen zur statischen Schubtragf?higkeit kleinskaliger Pin-Verbundmittel[J]. Stahlbau, 2016, 85(3):200-206.
[6] Xilin L,Ying Z,Hongmei Z,et al. Experimental study on seismic performance of steel fiber reinforced high strength concrete composite shear walls with different steel fiber volume fractions[J]. Engineering Structures, 2018, 171:247-259.
[7] Ren F,Chen J,Chen G,et al. Seismic behavior of composite shear walls incorporating concrete-filled steel and FRP tubes as boundary elements[J]. Engineering Structures, 2018, 168:405-419.
[8] Wijesiri Pathirana S,Uy B,Mirza O,et al. Flexural behaviour of composite steel–concrete beams utilising blind bolt shear connectors[J]. Engineering Structures, 2016, 114:181-194.
[9] Classen M,Hegger J.Assessing the pry-out resistance of open rib shear connectors in cracked concrete–Engineering model with aggregate interlock[J]. Engineering Structures, 2017, 148:254-262.
[10] Ataei A,Bradford M A,Liu X.Experimental study of composite beams having a precast geopolymer concrete slab and deconstructable bolted shear connectors[J]. Engineering Structures, 2016, 114:1-13.