Welcome to Francis Academic Press

Academic Journal of Engineering and Technology Science, 2021, 4(8); doi: 10.25236/AJETS.2021.040804.

Simulation Design of Single-phase AC Electronic Load

Author(s)

Yinuo Yang

Corresponding Author:
Yinuo Yang
Affiliation(s)

School of City College of Hebei University of Technology University, Tianjin 300000, China

Abstract

With the development of power electronics technology, a variety of power supplies are used in people's production and life. The characteristics of the power supply will greatly affect production and life. Therefore, it is necessary to conduct strict tests on the power supply. The traditional load has the disadvantage of consuming a lot of energy, and the AC electronic load solves the disadvantages brought by the traditional load.This paper takes single-phase AC electronic load as the research object. Based on the overall scheme design and topology research of the power electronic load system, the energy-consuming power electronic load is simulated first, the simulation model is constructed, and the main circuit is designed. Parameter, realize the load simulation function; further carry out the simulation research on the single-phase energy-fed power electronic load, the current generation unit design adopts PI+ repetitive control strategy, and the energy feedback unit adopts double closed-loop control strategy. After testing, the simulation current generation and energy are realized. The feedback function completes the overall simulation design of the single-phase AC electronic load.

Keywords

AC electronic load; energy feedback; repetitive control

Cite This Paper

Yinuo Yang. Simulation Design of Single-phase AC Electronic Load. Academic Journal of Engineering and Technology Science (2021) Vol. 4, Issue 8: 26-32. https://doi.org/10.25236/AJETS.2021.040804.

References

[1] Shi Y, Liu B, Duan S.Low-frequency input current ripple reduction based on load current feed-forward two-stage single-phase inverter[J].IEEE Transactions on Power Electronics, 2015, 31(11):7972-7985.

[2] Han Y, Fang X, Yang P, et al.Stability analysis of digital controlled single-phase inverter with synchronoreference frame voltage control[J].IEEE Transactions on Power Electronics, 2017:6333-6350.

[3] Fu X, Li S.Control of single-phase grid-connected converters with LCL filters using recurrent neurnetwork and conventional control methods[J].IEEE Transactions on Power Electronics, 2016, 31(7):5354-5364.

[4] A.Roshan,R.Burgos,A.C.Baisden,F.Wang,and D.Boroyevich,“AD-Q frame controller for a full-bridge single phase inverter used in small distributed power generation systems,”in Proc.IEEE Appl.Power Elec-tron.Conf. 2007, pp. 641–647.

[5] M. Ciobotaru, R.Teodorescu,and F.Blaabjerg,“A new single-phase PLL structure based on second order generalized integrator,”in Proc.37th IEEE Power Electron.Spec.Conf.2006,pp.1–6.

[6] Wang Hao. Research on energy feedback type AC electronic load [D]. Guangdong: Guangdong University of Technology, 2013.

[7] Sun Fengnan. Development of single-phase energy-fed power electronic load [D]. Shandong: Shandong University, 2011.

[8] Li Zhao, Shi Yanfei. Research on single-phase energy-fed AC electronic load [J]. Communication Power Technology, 2017, 34(01): 50-52+55.

[9] Chen Yiming. Research on control technology of single-phase photovoltaic grid-connected inverter [J]. Electrical Application, 2017, 36(21): 77-80.

[10] Shi Yanfei, Fang Yimin, Zhang Xiaojian. Research on grid-connected control of single-phase energy-fed AC electronic load[J]. Communication Power Technology, 2016, 33(01): 6-7+11.