Welcome to Francis Academic Press

International Journal of Frontiers in Engineering Technology, 2022, 4(3); doi: 10.25236/IJFET.2022.040305.

Analysis of Stator Core Magnetic Tension under Inter-turn Short Circuit of Excitation Winding

Author(s)

Xinghua Yuan1, Jia Qiang1,2

Corresponding Author:
Xinghua Yuan
Affiliation(s)

1Mechanical Engineering Department, North China Electric Power University, Baoding 071003, Hebei, China

2Xi'an Institute of Electromechanical Information Technology, Xi'an 710065, Shaanxi, China

Abstract

The characteristics of unbalanced magnetic tension of stator core before and after the inter-turn short circuit fault of excitation winding of synchronous generator are analyzed in this paper. Firstly, the expression of air gap magnetic density and stator core magnetic tension under normal condition and inter-turn short circuit fault of excitation winding are analyzed theoretically. Then, a two-dimensional model was established based on CS-5 synchronous motor, and nine force analysis points were set up in the stator core, what’s more, the magnetic tension simulation analysis was carried out for the nine analysis points. Finally, the mechanical response characteristics of the stator core under normal working conditions and inter-turn short circuit of excitation winding are verified by experiments. The experimental results are consistent with the theoretical analysis and simulation analysis results. The results show that even frequency doubling occurs in the air gap flux density after the inter-turn short circuit fault occurs in the field winding. The magnetic tension per unit area of the stator core has an odd frequency doubling, and the force increases with the increase of short circuit degree. The maximum stress point of the stator core is located at an Angle of about 45 degrees with the central axis of the big rotor tooth, which provides a basis for setting the stress monitoring point of the stator core and fault diagnosis.

Keywords

Excitation Winding; Inter-Turn Short Circuit; Magnetic Tension of Stator Core

Cite This Paper

Xinghua Yuan, Jia Qiang. Analysis of Stator Core Magnetic Tension under Inter-turn Short Circuit of Excitation Winding. International Journal of Frontiers in Engineering Technology (2022), Vol. 4, Issue 3: 28-41. https://doi.org/10.25236/IJFET.2022.040305.

References

[1] Hao Zhong. Analysis on Winding Electromagnetic Force Characteristics Under Air-gap Eccentricity and Interturn Short Circuit Compound Fault . Baoding: North China Electric Power University, 2017.

[2] Guangtao Zhang. On-line Monitoring and Positioning of Inter-turn Short Circuit in Fault Winding of Generator . Beijing: Beijing Jiaotong University, 2018.

[3] Yanjun Zhao. Analysis of rotor vibration characteristic for turbine generator rotor winding inter-turn short circuit fault . Journal of North China Electric Power University, 2008,35(05):16-21

[4] Yucai Wu, Yonggang Li, Wenzong Feng, Wenjing Zhang. Analysis on unbalanced magnetic pull generated by turn-to-turn short circuit of rotor windings within turbine generator . Electric Machines and Control, 2015,19 (03): 37-44.

[5] Shuting Wan, Longjiang Dou, Yu Zhang. Unbalanced Contrast of Calculation Method for Unbalanced Electromagnetic Force Under Rotor Inter-Turn Short Circuit Faults . Journal of Vibration, Measurement & Diagnosis, 2015,35 (04): 666-671 + 796.

[6] Shuting Wan, Yonggang Li. Influence of Factors Affecting Rotor Winding Inter-Turn Short Circuit on Generator Vibrations. Journal of Vibration, Measurement & Diagnosis, 2008,28 (02): 131-134 + 181.

[7] Yucai Wu, Wenzong Feng, Yonggang Li, Wenjing Zhang. Steady-state Electromagnetic Characteristics of Turbine Generator after Field Winding Short-circuit Fault . High Voltage Engineering, 2014,40 (05): 1567-1573.

[8] Liangliang Hao, Yuguang Sun, Arui Qiu. Electromagnetic Torque of Synchronous Generator with Inter-turn Short Circuit in the Field Winding. Automation of Electric Power Systems, 2011,35 (16): 59-65.

[9] Shuting Wan, Yu Zhang, Yuanyuan Hu. Analysis of Impact of Rotor Winding Inter-turn Short Circuit Faults on Electromagnetic Torque, 2012,16 (08): 17-22 + 28.

[10] Yu Zhang. Force Analysis of Generator Shaft with Winding Inter-turn Short Circuit Fault. Baoding: North China Electric Power University, 2013.

[11] Minghan Ma. Turbo-generator Excitation Winding Inter-turn Short Circuit Fault Compound Characteristics Analysis and Diagnosis. Baoding: North China Electric Power University, 2019.

[12] Yuling He. Analysis on Mechanical and Electrical Characteristics of Generator under Air-Gap Eccentricity and Winding Short Circuit Composite Faults . Baoding: North China Electric Power University, 2012.