Welcome to Francis Academic Press

Academic Journal of Engineering and Technology Science, 2022, 5(13); doi: 10.25236/AJETS.2022.051308.

Research Progress of Miniaturized Solid State Ion Selective Electrode

Author(s)

Wenpin Zhang1,2,3, Zhi Xiong1,2, Yong Huang1,2, Huasheng Xiao1,2, Xi Jia1,2, Shizhong Peng1,2, Yun Liu1,2, Shouliang Chen1,2, Chen Zong1,2

Corresponding Author:
Wenpin Zhang
Affiliation(s)

1Chongqing Special Equipment Inspection and Research Institute, Chongqing, 401121, China

2Key Laboratory of Electromechanical Equipment Security in Western Complex Environment for State Market Regulation, Chongqing, 401121, China

3Chongqing University, Chongqing, 400044, China

Abstract

Compared with the traditional liquid junction ion selective electrode, the all-solid-state ion selective electrodes have the advantages of miniaturization, miniaturization. The all-solid-state ion-selective electrode have been applied to on-site rapid detection in environmental testing, industrial analysis, and clinical testing. This paper focuses on the application of screen printing technology, paper chip technology and microfluidic technology in the miniaturization of solid-state ion selective electrodes, and looks forward to the future development trend.

Keywords

Ion selective electrode, All-solid-state, Miniaturized

Cite This Paper

Wenpin Zhang, Zhi Xiong, Yong Huang, Huasheng Xiao, Xi Jia, Shizhong Peng, Yun Liu, Shouliang Chen, Chen Zong. Research Progress of Miniaturized Solid State Ion Selective Electrode. Academic Journal of Engineering and Technology Science (2022) Vol. 5, Issue 13: 50-54. https://doi.org/10.25236/AJETS.2022.051308.

References

[1] Somer G, Kalayci S. A New and Simple Method for the Simultaneous Determination of Fe, Cu, Pb, Zn, Bi Cr, Mo, Se, and Ni in Dried Red Grapes Using Differential Pulse Polarography [J]. Food Analytical Methods, 2015, 8(3): 604-611.

[2] TURNER Anthony P F. Biosensors: sense and sensibility [J]. ChemicalSociety Reviews, 2013, 42(8): 3184-3196.

[3] Cattrall R W, Freiser H. Coated-wire ion-selective electrodes [J]. Analytical Chemistry, 1971, 43(13): 1905-1906.

[4] Faridbod F, Dinarvand R. Developments in the Field of Conducting and Non-conducting Polymer Based Potentiometric Membrane Sensors for Ions Over the Past Decade [J]. Sensors, 2008, 8: 2331-2412.

[5] Qing bo An,Fei Jia,Jianan Xu.Recent progress of all solid state ion selective electrode[J]. SCIENTIA SINICA Chimica, 2017, 47(5): 524-531.

[6] Hu J, Stein A. Rational design of all-solid-state ion-selective electrodes andreference electrodes [J]. Trends in Analytical Chemistry, 2016, 76(2016): 102-114.

[7] Musa A E, Campo F D, Abramova N, et al. Disposable Miniaturized Screen-Printed pH and Reference Electrodes for Potentiometric Systems [J]. Electroanalysis, 2011, 23: 115-121.

[8] Guinovart T, Bandodkar A J, Windmiller J R, et al. A potentiometric tattoo sensor for monitoring ammonium in sweat [J]. Analyst, 2013, 138(22): 7031-7038.

[9] Zoerner A, Oertel S, Jank M P M, et al. Human Sweat Analysis Using a Portable Device Based on a Screen-printed Electrolyte Sensor [J]. Electroanalysis, 2018, 30(4): 665-671.

[10] Xavier Rius-Ruiz F, Crespo G A, Bejarano-Nosas D, et al. Potentiometric Strip Cell Based on Carbon Nanotubes as Transducer Layer: Toward Low-Cost Decentralized Measurements [J]. Analytical Chemistry, 2011, 83(22): 8810-8815.

[11] Bouri M, Zuaznabar-Gardona J C, Novell M, et al. Paper-based Potentiometric Biosensor for Monitoring Galactose in Whole Blood [J]. Electroanalysis, 2021, 33(1): 81-89.

[12] Ferguson S A, Meyerhoff M E. Polyion Detection via All-solid-contact Paper-based Polyion-sensitive Polymeric Membrane Electrodes [J]. Electroanalysis, 2019, 31(8): 1433-1437.

[13] Hu J B, Zhao W Y, Buhlmann P, et al. Paper-Based all-solid-state Ion-Sensing Platform with a Solid Contact Comprising Colloid-Imprinted Mesoporous Carbon and a Redox Buffer [J]. Acs Applied Nano Materials, 2018, 1(1): 293-301.

[14] Armas S M, Manhan A J, Younce O, et al. Ready-to-use single-strip paper based sensor for multiplex ion detection [J]. Sensors and Actuators B-Chemical, 2018, 255: 1781-1787.

[15] Min X, Bao C, Kim W S. Additively Manufactured Digital Microfluidic Platforms for ion selective Sensing [J]. Acs Sensors, 2019, 4(4): 918-923.

[16] Gallardo-Gonzalez J, Baraket A, Boudjaoui S, et al. A fully integrated passive microfluidic Lab-on-a-Chip for real-time electrochemical detection of ammonium: Sewage applications [J]. Science of the Total Environment, 2019, 653: 1223-1230.

[17] Wu C X, Selberg J, Nguyen B, et al. A Microfluidic Ion Sensor Array [J]. Small, 2020, 16(6): 1906436−1906442.

[18] Matzeu G, O'Quigley C, McNamara E, et al. An integrated sensing and wireless communications platform for sensing sodium in sweat [J]. Analytical Methods, 2016, 8(1): 64-71.

[19] Gosselin D, Gougis M, Baque M, et al. Screen-Printed Polyaniline-Based Electrodes for the Real-Time Monitoring of Loop-Mediated Isothermal Amplification Reactions [J]. Analytical Chemistry, 2017, 89(19): 10124-10128.

[20] Farzbod A, Moon H. Integration of reconfigurable potentiometric electrochemical sensors into a digital microfluidic platform [J]. Biosensors & Bioelectronics, 2018, 106: 37-42.